Compact Intelligent Addressable Fire Alarm Panel
TFP-1111
Compact Intelligent Addressable Fire Alarm Panel
TFP-1111 is a compact, intelligent, addressable fire alarm control panel designed in accordance with EN 54 standards for small and medium-sized fire detection and alarm systems. Supporting 1 addressable loop, 16 zones, and up to 130 addressable devices, TFP-1111 delivers reliable fire detection, flexible configuration, and advanced communication capabilities.
- EN 54-2, EN 54-4 and EN 54-21 compliant
- 1 addressable loop, up to 130 devices
- 16 programmable fire zones
- Teknim Flashlink loop communication protocol
- 2 programmable siren outputs (monitored)
- 3 relay outputs (1 fault + 2 programmable)
- 2 supervised inputs (supports conventional detectors and MCPs)
- Alarm dependency functions (general & zone-based)
- Configurable output delays (general and zonal)
- Test and disable modes for zones, devices, and outputs
- 4095 event log with date & time stamping
- Built-in BLE for local monitoring (Teknim Assistant)
- USB connection for configuration and monitoring
- Optional LTE (TXM-5474) and Ethernet (TXM-5271) communication
- Optional TdNET networking (up to 16 panels)
- Teknim Mosaic Cloud & ARC connectivity
- SMS notification support (up to 8 users – via LTE)
- Multi-language support with replaceable language labels
- Internal cabinet illumination for easy installation
- Optional flush mounting accessory (TFA-0111)
| Voltage | 230 / 115 VAC (+%10 / -%15) |
|---|---|
| Frequency | 50 / 60 Hz (±%5) |
| Mains Input Fuse | 3 A |
| Output Voltage | 21 – 29 Vdc (±%2) (24 Vdc nominal) |
| Output Fuse | 30 Vdc, 5 A |
| Cable Type | 3 x 1,5mm² (Phase, Neutral, Ground) |
| Backup Power Supply | 2 x 12V, 7Ah dry Type leak-proof (Recommended; Yuasa NP7-12) |
| Backup Power Supply Cut Off Voltage | 20 Vdc |
| Backup Power Supply Fuse | 30 Vdc, 5 A |
| Backup Power Supply Maximum Internal Resistance | 2.2 ohm (Ri max.) |
| Charging Voltage | 27,6 Vdc @20°C, temperature compensation |
| Charging Current | 500 mA |
| I min. | 150 mA |
| I max. a | 1 A |
| I max. b | 1.5 A |
| Number of Device | 130 |
| Number of Zones | 16 |
| Output Voltage | 36V (Range 18VDC – 36VDC) |
| Output Current | 500 mA |
| Sounder Outputs | 2 |
| Output Voltage | 18-27.6 Vdc |
| Sounder Fuse | 500mA per siren |
| End of Line Resistance | 4k7 ohm, %1, 1/4W |
| Number of Supervised Inputs | 2 |
| Output Voltage | 17.5-27.6 Vdc |
| Output Current | 54mA, max(short circuit) |
| MCP Detection Resistance | 50-250 ohm |
| End of Line Resistance | 4k7 ohm, %1, 1/4W |
| Number of Relays | 3 (1 General Fault, 2 Programmable) |
| Relay Contacts | 30 VDC, 2A max |
| Aux Output | 17.5-27.6 VDC |
| Aux Fuse | 30 VDC, 500 mA |
| Repeater Output | 17.5-27.6 VDC |
| Repeater Fuse | 30VDC, 500mA |
| Teknim Cloud | via TXM-5271 or TXM-5474 (Monitoring) |
| Teknim Local | via USB (Monitoring/Configuration) |
| Teknim Asistant | via BLE (Monitoring) |
| SMS | via TXM-5474 (up to 8 Users) |
| ARC (Alarm Receiving Centre) | via TXM-5271 or TXM-5474 |
| IP Class | IP30 |
| Environmental Class | Class A |
| Temperature | -5°C ~ +40°C |
| Humidity | 95% RH (max) |
| Dimensions | 376 x 267 x 113 mm |